POLYETHYLENE PUMP CHAMBERS

DrainAce® Polyethylene Pump Chambers


The DrainAce range of polyethylene pump chambers is an ideal solution for sewer, effluent, stormwater and trade waste applications, providing durable and customisable containment for both residential and commercial systems. Manufactured from corrosion-resistant polyethylene, these chambers offer excellent strength, flexibility, and long-term performance in underground or above-ground installations.


With a wide selection of sizes and cover types available, DrainAce polyethylene pump chambers can be tailored to suit virtually any project requirement – from small domestic pump wells to large commercial drainage systems.

FEATURES

APPLICATIONS

The DrainAce Compact is commonly found in restaurants, basements of high-rise buildings, boardrooms, laboratories, doctor or dental surgeries, construction sites and portable buildings. Units are also available for greasy waste discharge from grease arrestors. 

APPLICATIONS


Global Water’s DrainAce pump chambers are commonly found in the following applications:

  • Domestic and residential sewage or septic effluent
  • Commercial trade waste or buffer storage
  • Stormwater detention or discharge
  • Rainwater harvesting
  • Settling and filtration tanks
  • Emergency storage or overflow containment.

DOWNLOADS

VIDEOS

PRODUCT INFORMATION


Polyethylene chamber

DrainAce pump chambers are made from linear low-density polyethylene (LLDPE), a tough and lightweight material with high impact resistance and excellent chemical durability. All models are engineered using FEA modelling and ultrasonic wall testing, ensuring compliance with loading requirements.

Chambers are available in a wide range of sizes – from 175 L to 10,500 L – with varying diameters and depths to suit site-specific needs such as shallow rock installs or deep narrow pits with low inlet levels. Above-ground versions are also available for use in chemical storage, mixing, or emergency containment.

Each chamber is manufactured to strict ISO9001:2015 quality standards and is certified to AS/NZS 1546.1, with Department of Health approvals on applicable models.

Cover options

A wide variety of cover options are available to suit both load requirements and access needs. These include:

  • Foam-filled polyethylene covers for non-traffic areas
  • Composite resin gas-tight covers rated to 510 kg (AS/NZS 1546.1 compliant)
  • Light or heavy-duty cast iron gas-tight covers
  • Galvanised steel covers and grates for light or Class D loading

Covers can be selected based on load class, access type and environmental sealing requirements. Some options may require a concrete surround for full load-bearing performance.

Features

  • Largest range of polyethylene chambers in Australia
  • Diameters up to 1950 mm
  • Depths up to 5.2 m
  • Capacities from 175 L to 10,500 L
  • Above and below-ground options available
  • Corrosion-resistant and fully recyclable
  • Flexibility for custom inlet and outlet fittings
  • 510 kg top load tested (composite cover)
  • Ultrasonic wall thickness tested
  • Compliant with AS/NZS 1546.1
  • Approved by NSW and SA Department of Health
  • Manufactured to ISO9001:2015 quality standards.



Pit specifications

Pit model Capacity (L) Diameter (mm) Nominal depth (mm) Weight (kg) Cover size (mm)
DAP01* 175 7102 660 8 600 x 600
DAP02* 280 7102 960 16 600 x 600
DAP02A* 250 615 960 19 600 x 600
DAP05* 500 700 1400 28 Ø560
DAP06A 590 800 1260 33 Ø600
DAP09 950 1000 1440 60 600 x 600
DAP10A 1050 1000 1600 73 600 x 600
DAP15 1460 1000 2100 97 600 x 600
DAP19 1880 1400 1525 128 900 x 600
DAP22 2180 1000 3150 235 600 x 600
DAP31 3150 1400 2385 210 900 x 600
DAP32 3200 1950 1400 190 900 x 600
DAP41 4100 1400 3020 310 900 x 600
DAP52 5200 1950 2100 355 900 x 600
DAP61 6100 1950 2400 471 900 x 600

Special order

Pit model Capacity (L) Diameter (mm) Nominal depth (mm) Weight (kg) Cover size (mm)
DAP03A* 320 615 1220 23 690 x 690
DAP04* 450 670 1410 30 Ø600
DAP10P 1050 850 2160 70 Ø600
DAP28 2800 1400 2110 160 900 x 600
DAP45 4500 1400 3295 380 900 x 600
DAP60 6000 1400 4210 425 900 x 600
DAP71 7000 1400 5120 633 900 x 600
DAP40 4000 1950 1700 269 900 x 600
DAP69 6900 1950 2700 415 900 x 600
DAP81 8100 1950 3180 545 900 x 600
DAP105 10,500 1950 4050 770 900 x 600

* Does not comply with AS/NZS 1546.1 and not Department of Health approved.
† Department of Health approved (NSW only).
All other models are approved by NSW and SA Department of Health.
‡ AS/NZS 1546.1 certification and Department of Health approval pending.


Cover types

Reference code Loading Type
LSP No traffic Poly cover
LSGC Foot traffic Galvanised cover – gas-tight
LSCR Light duty – 510 kg Composite cover – gas-tight
LSCI Light duty – Class B Cast iron cover – gas-tight*
HSCI Heavy duty – Class D Cast iron cover – gas-tight*
LSGG Light duty Galvanised grate
HSGG Class D Galvanised grate*

*Requires load-bearing concrete surround

Put some clear and concise content in here. Keep your reader in mind. What are they trying to do? What are they hoping to learn? Why are they reading this? Help them out and use the tone and voice of your organization.

Put some clear and concise content in here. Keep your reader in mind. What are they trying to do? What are they hoping to learn? Why are they reading this? Help them out and use the tone and voice of your organization.

INDUSTRY SUPPORT

Register now for access to our product drawing library

You will be granted permission to view and download our PDF and DWG files of selected pump stations and pressure systems.

Drawings-CTA
Enquire here for more information or to request a quote: