Put some clear and concise content in here. Keep your reader in mind. What are they trying to do? What are they hoping to learn? Why are they reading this? Help them out and use the tone and voice of your organization.
EcoTreat Class 1 Bypass BP Series | Oil Water Separator
The Global Water EcoTreat Class 1 Oil/Water Bypass Separator is an in-line device designed to treat stormwater run-off from paved areas where low levels of hydrocarbon residuals and gross pollutants are present, whilst allowing high flows to pass without restriction.
Features of the bypass device include:
The DrainAce Compact is commonly found in restaurants, basements of high-rise buildings, boardrooms, laboratories, doctor or dental surgeries, construction sites and portable buildings. Units are also available for greasy waste discharge from grease arrestors.
The EcoTreat Class 1 Bypass Separator is suitable for the following applications:
The Bypass Oil/Water separator is suitable for primary and secondary treatment in low risk areas, removing hydrocarbons and suspended solids, whilst preventing on-site flooding from storm events.
Full-scale performance testing of the EcoTreat Class 1 Bypass Separator was conducted by the University of South Australia in accordance with Stormwater Australia guidelines for suspended solids and nutrient removal. The unit achieved Class 1 gravity supply device requirements, in accordance with EN 858-1.
For full details on certified MUSIC modelling, please contact Global Water.
Model |
BP-35 |
BP-60 |
BP-125 |
BP-225 |
Treatment flow rate (L/S) |
7 |
12 |
25 |
45 |
Bypass flow rate (L/s) |
35 |
60 |
125 |
225 |
Capacity (L) |
1730 |
2200 |
3720 |
7000 |
Diameter (mm) |
1300 |
1850 |
1850 |
2300 |
Height (mm) |
1940 |
1585 |
2210 |
2220 |
Weight (kg) |
98 |
163 |
211 |
260 |
Inlet diameter (mm) |
160/200/250/315 |
200/400 |
315/400 |
315/400 |
Outlet diameter (mm) |
160/200/250/315 |
200/250/315/400 |
315/400 |
315/400 |
Oil storage volume (L) |
70 |
120 |
250 |
400 |
Sediment storage volume (L) |
700 |
1200 |
2000 |
4000 |
Note: the treatment flow rate depicts the maximum flow the EcoTreat Bypass Separator can treat through the coalescing unit, while the bypass flow rate is the maximum rate at which partially treated flow moves through the unit in a storm event.
Put some clear and concise content in here. Keep your reader in mind. What are they trying to do? What are they hoping to learn? Why are they reading this? Help them out and use the tone and voice of your organization.
Put some clear and concise content in here. Keep your reader in mind. What are they trying to do? What are they hoping to learn? Why are they reading this? Help them out and use the tone and voice of your organization.
Put some clear and concise content in here. Keep your reader in mind. What are they trying to do? What are they hoping to learn? Why are they reading this? Help them out and use the tone and voice of your organization.
Looking for industrial and mining pumps?
Visit Global Pumps
12 Selgar Avenue Tonsley